Home >> Company News
Digital refractometer models and specifications
Views : 2956
Update time : 2013-03-05 18:06:00
Digital refractometer models and specifications .pdf
| Products | NO. | Ticks name | Ticks No. | Measuring range | Resolution | Accuracy |
| Brix | DR-101 | Brix | S01 | 0.0-50.0% | 0.10% | ±0.2% |
| Refractive Index | S02 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| DR-102 | Brix | S01 | 0.0-90.0% | 0.10% | ±0.2% | |
| Refractive Index | S02 | 1.3330-1.5177nD | 0.0001nD | ±0.0003nD | ||
| DR-103 | Dextran | S01 | 0.0--10.6% | 0.10% | ±0.2% | |
| Fructose | S02 | 0.0--68.9% | 0.10% | ±0.2% | ||
| Glucose | S03 | 0.0--59.9% | 0.10% | ±0.2% | ||
| Lactose | S04 | 0.0--16.5% | 0.10% | ±0.2% | ||
| Maltose | S05 | 0.0--15.60% | 0.10% | ±0.2% | ||
| Refractive Index | S06 | 1.3330-1.4200nD | 0.0001nD | ±0.0003nD | ||
| Salinity | DR-201(sodium chloride NaCl) | salinity | S01 | 0.0--28.0% | 0.10% | ±0.2% |
| salinity | S02 | 0--280‰ | 1‰ | ±2‰ | ||
| specific gravity | S03 | 1.000-1.217 | 0.001 | ±0.002 | ||
| Refractive Index | S04 | 1.3330--1.3900nD | 0.0001nD | ±0.0003nD | ||
| DR-202(sea water) | salinity | S01 | 0--100‰ | 1‰ | ±2‰ | |
| chlorinity | S02 | 0--57‰ | 1‰ | ±2‰ | ||
| specific gravity | S03 | 1.000-1.070 | 0.001 | ±0.002 | ||
| Refractive Index | S04 | 1.3330--1.3530nD | 0.0001nD | ±0.0003nD | ||
| Honey | DR-301 | Brix | S01 | 0.0--90.0% | 0.10% | ±0.2% |
| Water | S02 | 38.0%-5.0% | 0.10% | ±0.2% | ||
| Be' | S03 | 33.0-48.0 | 0.1 | ±0.2% | ||
| Refractive Index | S04 | 1.3330--1.5177nD | 0.0001nD | ±0.0003nD | ||
| Wine | DR-401 | Brix% | S01 | 0.0-45.0% | 0.10% | ±0.2% |
| %VOL ap | S02 | 0.0-22.0% | 0.10% | ±0.2% | ||
| Oe | S03 | 3-150 | 1 | ±2% | ||
| KMW | S04 | 0.0-25.0 | 0.1 | ±0.2 | ||
| Clinical | DR-501 | URINE SP. G. | S01 | 1.000-1.050 | 0.001 | ±0.002 |
| SERUM P. | S02 | -12.1 | 0.1 | ±0.2 | ||
| Refractive Index | S03 | 1.3330--1.3900nD | 0.0001nD | ±0.0003nD | ||
| Car | DR-601 | Cleaner | S01 | (0)―(-40)℃ | 0.1℃ | ±0.5℃ |
| Ethylene Glycol | S02 | (0)―(-50)℃ | 0.1℃ | ±0.5℃ | ||
| Propylene Glycol | S03 | (0)―(-50)℃ | 0.1℃ | ±0.5℃ | ||
| Battery | S04 | 1.000―1.500sg | 0.001 | ±0.005sg | ||
| DR-602(Urea Tester) | Urea (NH2)2C0 | S01 | 0-51.0% | 0.1% | ±0.2% | |
| Refractive Index | S02 | 1.3330--1.4056nD | 0.0001nD | ±0.0003nD | ||
| LHDR-603(Engine Coolant Tester) | Ethylene Glycol (v/v) | S01 | 0-100% | 0.10% | ±0.5% | |
| Ethylene Glycol (℃ ) | S02 | (0)―(-50)℃ | 0.1℃ | ±0.5℃ | ||
| Propylene Glycol (v/v) | S03 | 0-100% | 0.10% | ±0.5% | ||
| Propylene Glycol (℃ ) | S04 | (0)―(-60)℃ | 0.1℃ | ±0.5℃ | ||
| DR-604(Brake Fluid Tester ) | DOT3 | S01 | (121)―(260)℃ | 0.1℃ | ±0.5℃ | |
| DOT3 HT | S02 | (121)―(299)℃ | 0.1℃ | ±0.5℃ | ||
| DOT4 | S03 | (125)―(275)℃ | 0.1℃ | ±0.5℃ | ||
| DOT4 Plus | S04 | (150)―(275)℃ | 0.1℃ | ±0.5℃ |